Electronic shear pin
Total process protection with electronic torque overload protection
The unique electronic circuitry within the Zener ESP system monitors certain characteristics of the motor/gearbox to closely approximate the output torque of the drive system. Should the output torque of the motor/gearbox exceed the desirable preselected limit, for a pre-selected time, the ESP system will automatically disconnect the motor from it’s electrical supply, ensuring complete protection for the entire process.
Suitable for single phase and 3-phase motors
The ESP is designed for single phase or three phase motors of any size.
More accurate maximum torque protection
- Adjustable ‘Overload Trip Point’ can be accurately set to any desired level from 0-150% of motor/gearbox full load torque, ensuring reliable process protect ion every time.
- Does not rely on the total motor current only. The ESP’s superior electronics accurately monitor a selection of motor/gearbox characteristics to determine the torque output of the drive system.
- The Zener ESP incorporates an adjustable ‘Motor Start Time’ to enable the motor/gearbox to reach full running speed without nuisance tripping.
- An adjustable ‘Trip Time Delay’ is provided to eliminate nuisance tripping during momentary overloads when automatic shutdown is not required.
Easier to install
- The ESP’s simple wiring requirements makes the Zener ESP system easy to install in new or existing equipment.
- An internal test signal is provided for easy and quick calibration of the ESP ‘Overload Trip Point’, ‘Motor Start Time’ and ‘Trip Time Delay’ periods and subsequent testing of System operation.
- The ESP can be supplied on a baseplate complete with C.T.
No maintenance requirements
- The Zener ESP eliminates lengthy and costly mechanical repairs or process downtime due to overload/ over torque damage.
- The ESP’s highly reliable electronic componentry requires no regular maintenance schedule or down time for inspection.
Convenient, efficient and safe
- The Zener ESP can be instantly reset at the push of a button, no process downtime for mechanical repairs.
- The ESP can be adjusted at any time without stopping the machine.
- Operation safety is assured when resetting the ESP after an automatic shut-down as the motor requires re-starting from its independent control system.
- The ESP’s operation can be tested at any time whilst the motor is operating or stationary.
- LEDs provide indication of internal functions and to assist with the calibration of operating parameters.